Product Details:
| Minimum Order Quantity | 1 Piece |
| Manufacturer Series | S7 ET 200 CPU |
| Communication Protocols | Profibus |
| Mounting Type | DIN Rail |
| Output Type | Digital |
| Country of Origin | Made in India |
CPU 1514SP-2 PN 6ES75142DN030AB0
CPU 1514SP-2 PN 6ES7514-2DN03-0AB0
6ES7514-2DN03-0AB0
6ES75142DN030AB0
SIEMENS ET200SP CPU 1214SP-2PN
General information Product type designation CPU 1514SP-2 PN HW functional status FS01 Firmware version V3.0 Product function ● I&M data Yes; I&M0 to I&M3 ● Module swapping during operation (hot swapping) Yes; Multi-hot swapping ● Isochronous mode Yes; only with PROFINET; with minimum OB 6x cycle of 375 µs Engineering with ● STEP 7 TIA Portal configurable/integrated from version V18 (FW V3.0) Configuration control via dataset Yes Control elements Mode selector switch 1 Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes Mains buffering ● Mains/voltage failure stored energy time 10 ms Input current Current consumption (rated value) 0.51 A Current consumption, max. 0.7 A Inrush current, max. 1.34 A; Rated value I²t 0.3 A²·s Power Infeed power to the backplane bus 8.05 W Power loss Power loss, typ. 3.5 W Memory Number of slots for SIMATIC memory card 1 SIMATIC memory card required Yes Work memory ● integrated (for program) 600 kbyte ● integrated (for data) 3.5 Mbyte Load memory ● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
CPU processing times for bit operations, typ. 6 ns for word operations, typ. 7 ns for fixed point arithmetic, typ. 9 ns for floating point arithmetic, typ. 37 ns CPU-blocks Number of elements (total) 8 000; Blocks (OB, FB, FC, DB) and UDTs DB ● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 ● Size, max. 3.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB FB ● Number range 0 ... 65 535 ● Size, max. 600 kbyte FC ● Number range 0 ... 65 535 ● Size, max. 600 kbyte OB ● Size, max. 600 kbyte ● Number of free cycle OBs 100 ● Number of time alarm OBs 20 ● Number of delay alarm OBs 20 ● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs ● Number of process alarm OBs 50 ● Number of DPV1 alarm OBs 3 ● Number of isochronous mode OBs 1 ● Number of technology synchronous alarm OBs 2 ● Number of startup OBs 100 ● Number of asynchronous error OBs 4 ● Number of synchronous error OBs 2 ● Number of diagnostic alarm OBs 1 Nesting depth ● per priority class 24 Counters, timers and their retentivity S7 counter ● Number 2 048 Retentivity — adjustable Yes IEC counter ● Number Any (only limited by the main memory) Retentivity — adjustable Yes S7 times ● Number 2 048 Retentivity — adjustable Yes IEC timer ● Number Any (only limited by the main memory) Retentivity — adjustable Yes Data areas and their retentivity Retentive data area (incl. timers, counters, flags), max. 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB Flag ● Size, max. 16 kbyte ● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte Data blocks ● Retentivity adjustable Yes ● Retentivity preset No